RECOMMENDED OPERATING CONDITIONS
Room temperature 70°F -90°F (21 ÷ 32°C)
TECHNICAL SPECIFICATION
Power supply see rating plate
Max. absorbed power
in air conditioning
Refrigerating capacity
Refrigerant
Number of fan speeds 2
Max. air flow . 370 m3/h
Dimensions:
width 580 mm 22
21
/
64
height 785 mm 30
13
/
32
depth 435 mm 17
1
/
8
This appliance contains substances which, if released into the atmosphere, would damage the
ozone layer. Care should therefore be taken not to perforate the refrigerant circuit. At the end of
its working life, take the air conditioning unit to a special collection Delonghi center.
If the unit is not working properly, this may be due to small problems check you can easily resolve your-
self. Follow these instructions carefully before contacting your local Authorized Delonghi Technical Ser-
vice Center.
Troubleshooting/
Technical specification
PROBLEM SOLUTION
The air conditioner is
completely turned
off
It is not plugged in
There is no electricity
plug in
CAUSE
The unit works but
does not cool the
room
Three minutes have not passed since it was
turned on
•Windows open
•A heat source is operating in the room (burner,
light, etc.) or there are a lot of people
The air outlet hose has detached from the
coupling
Thermostat adjusted too high
Air filters clogged
The output of the unit is insufficient for the con-
ditions or size of the room
•Wait three minutes (safety devi-
ce) and the appliance should
start cooling.
Close the windows
Eliminate heat sources
Fit the hose in the coupling
Lower the thermostat
• Clean/replace filters
The air conditioner is
on (signal light )
but the appliance
doesn't start
10
The notches of the timer are in the rest mode
Proceed with a new timr set-
ting.
The unit works for
only a short time
There is a kink in the exaust hose
The exaust hose is blocked
There are too many curves in the outlet tube
The fan is blocked
Position the exaust hose cor-
rectly
Check that there are no
blockages preventing the
discharge of air to the outside
Rearrange the hose correctly
Contact the De’Longhi Servi-
ce Center