1. After connecting the gas supply, check the piping and connections for leaks
using a soap and water solution. The presence of bubbles indicates a leak, tight-
en or replace connections as appropriate.
Warning: Do not use any naked flame to check for leaks.
2. The operation of the appliance MUST be tested before leaving.
3. Adjust the test point pressure or supply pressure to the value which is appropri-
ate for the gas type.
4. Turn on the appliance gas controls and light each burner. Check for a well
defined blue flame without any yellow tipping. If any abnormality is evident then
check that the burner cap is located properly and the injector nipple is aligned
correctly.
5. Check the minimum burner setting by quickly rotating the gas control knob from
the maximum to the minimum position, the flame must not go out. If adjust-
ment is required carry out the “minimum burner setting adjustment" procedure
described below.
6. If satisfactory performance cannot be obtained, the installer shall check the instal-
lation and notify the local gas supply authority for a gas supply problem, or if it
is an appliance problem, our Customer Service Centre should be called to obtain
the nearest authorized Delonghi Service Agent.
7. Where the appliance data plate cannot be easily read with the appliance in the
installed position the duplicate data plate must be attached to adjacent surface
and the duplicate Propane Gas conversion label should also be included where
a Propane Gas conversion has been completed.