(Note: Gas type sticker and data plate are attached to the underside of the base of
the appliance.)
CONVERSION PROCEDURE (to convert to LPG Propane)
The conversion procedure must be carried out only by an authorised person.
After the conversion procedure has been completed, as described in the instruction man-
ual, affix to the appliance the warning label stating that the cooktop has been converted
for use with Propane Gas (supplied with the Propane Gas conversion kit.). A second
Propane Gas conversion label should also be affixed to an adjacent surface along with
the duplicate data plate.
Note: Servicing of this appliance is only to be carried out by Authorised
Persons.
TABLE FOR THE CHOICE OF THE INJECTORS
Natural Gas Propane Gas
Test Point
1.0 2.75
Pressure (kPa)
Burner Injector Orifice Gas Consumption Injector Orifice Gas Consumption
[mm] [MJ/h] [mm] [MJ/h]
Semi-rapid 1.12 6.30 0.70 6.30
Rapid 1.45 10.80 0.91 10.80
Triple ring 1.65 12.60 0.95 12.60