GAS SUPPLY:
■ This appliance is suitable for use with Natural Gas or Propane Gas. (Check the
“gas type” sticker attached to the appliance).
■ For Natural Gas the gas supply must be regulated to obtain a pressure of 1 kPa
with the two largest burners operating.
■ For Propane Gas models connect the gas supply directly to the appliance test
point adaptor (supplied with the conversion kit) and ensure that the supply pres-
sure is regulated to 2.75 kPa.
■ Do NOT force the ”elbow“ rotation prior to loosening nut.
■ Do NOT over tighten the nut at the ”elbow“.
Gas connection for
NATURAL GAS
Figure 9
Figure 8
Gas connection for
PROPANE GAS
Gas inlet pipe
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Test point adaptor
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Gas inlet pipe
9
Test
point
Test
point